Circuit Breaker
VCB
Features
Joongwon’s vacuum circuit breaker adopts the VI(Vacuum Interrupter) that uses vacuum as the insulation medium and thus are easy and safe to use with its superb circuit breaking capacity. In particular, it was first developed in the country by applying the IEC 62271-100 and designed to be much smaller and lighter at its optimal state.
- Excellent breaking capacity
The current breaking time is very short, and the insulation recovery features are wonderful. It also presents the most stable breaking performance with no potential danger of restrike or reignition. - Easy repair and maintenance
Its outstanding electrical and mechanical durability makes it unnecessary special repair or maintenance even for a long-term use. There are various options including the fixed and the draw-out type. And it’s easy to install, repair and check thanks to the compact design. - High reliability
Its top durability is guaranteed with more than 10,000 times of operation tests, which makes it the perfect breaking choice for a situation requiring frequent breaking.
In addition, it’s stable in the mechanical and electrical aspect - High quality
It’s compliance with international standard as applying the latest standard IEC 62271-100 developed it. - High speed re-closing
It can serve as a high speed-reclosing breaker that is needed to avoid the damage by a lightning impulse or a temporary earth fault.
Operating Sequence O-0.3sec-CO-3min-CO
■ Mounting style
It has three types of fixed and draw-out, F2 class according to installation methods. The latter one has the main body of the breaker connected or detached at the mainbus.
Ratings
Type | JWV708 | JWV712 | JWV720-630 | JWV720-1250 | JWV731-630 | JWV731-1250 | JWV731-2000 |
---|---|---|---|---|---|---|---|
Mounting method | Fixed, Draw-out, F2 class | ||||||
Rated voltage(kV) | 3.6 / 7.2 | ||||||
Rated current(A) | 400 | 630 | 1250 | 630 | 1250 | 2000 | |
Rated power frequency(Hz) | 60(50) | ||||||
Rated short-circuit breaking current(kA) | 8 | 12.5 | 20 | 31.5 | |||
Rated short-circuit making current(kA) | 20 | 32 | 52 | 81 | |||
Rated breaking capacity(MVA) | 20 / 100 | 77 / 155 | 124 / 249 | 196 / 392 | |||
Rated short time withstand current(kA 1sec) | 8 | 12.5 | 20 | 31.5 | |||
Rated power frequency withstand voltage(kA)(rms) | 20(1min) | ||||||
Rated lighting impulse withstand voltage(kV)(Peak) | 60(1.2×50㎲) | ||||||
No-load closing time(s) | ≤ 0.1 sec | ||||||
Opening time(s) | ≤ 0.1 sec | ||||||
Rated short circuit breaking time(Cycle) | 2 | 3 | 5 | ||||
Operating duty | O – 0.3 sec – CO – 3min – CO | ||||||
Applied standard | IEC 62271-100 | ||||||
Spring charge method | PermanentMagnetic Actuator | spring charge | |||||
Tripping method | PermanentMagnetic Actuator | Shunt trip | |||||
Rated motor operating voltage(V) | DC 110V | ||||||
Rated closing control voltage(V) | DC 110V | ||||||
Rated tripping control voltage(V) | DC 110V | ||||||
Raged closing control current(A) | less than 20A | less than 5A | |||||
Rated tripping control current(A) | less than 20A | less than 5A | |||||
Motor operating current(A) | – | less than 5A | |||||
Aux. contact | 4a4b(Standard), 7a7b(Can be added on order) | ||||||
Mechanical endurance | M2 (10,000) | M1 (2,000) / M2 (10,000) | |||||
Electrical endurance | E1 | ||||||
Restrike class | C2 | ||||||
Cable charging current(A) | 10 |
Ratings
Type | JWV 1525-630 |
JWV 1525-1250 |
JWV 1525-2000 |
JWV 2412-630 |
JWV 2412-1250 |
JWV 2425-630 |
JWV 2425-1250 |
JWV 2425-2000 |
---|---|---|---|---|---|---|---|---|
Mounting method | Fixed, Draw-out, F2 class | |||||||
Rated voltage(kV) | 12 / 15 | 24 | ||||||
Rated current(A) | 630 | 1250 | 2000 | 630 | 1250 | 630 | 1250 | 2000 |
Rated power frequency(Hz) | 60(50) | |||||||
Rated short-circuit breaking current | 25 | 12.5 | 25 | |||||
Rated short-circuit making current | 65 | 32 | 65 | |||||
Rated breaking capacity | 650 | 520 | 1039 | |||||
Rated short time withstand current | 25 | 12.5 | 25 | |||||
Rated power frequency withstand voltage | 36(1min) | 60(1min) | ||||||
Rated lighting impulse withstand voltage | 95(1.2×50㎲) | 125(1.2×50㎲) | ||||||
No-load closing time | ≤ 0.1 sec | |||||||
Opening time | ≤ 0.1 sec | |||||||
Rated short circuit breaking time | 3 | 5 | ||||||
Operating duty | O – 0.3 sec – CO – 3min – CO | |||||||
Applied standard | IEC 62271-100 | |||||||
Spring charge method | spring charge | |||||||
Tripping method | Shunt trip | |||||||
Rated motor operating voltage | DC 110V | |||||||
Rated closing control voltage | DC 110V | |||||||
Rated tripping control voltage | DC 110V | |||||||
Raged closing control current | less than 5A | |||||||
Rated tripping control current | less than 5A | |||||||
Motor operating current | less than 5A | |||||||
Aux. contact | 4a4b(Standard), 7a7b(Can be added on order) | |||||||
Mechanical endurance | M1 (2,000) / M2 (10,000) | M2 (10,000) | ||||||
Electrical endurance | E1 | |||||||
Restrike class | C2 | |||||||
Cable charging current | 10 | 31.5 |